Contained in the zip file will be the validated version of firmware (.cmp), as well
as any supplemental configuration files, and a sample .ini file.
5 Configuration
Methods:
Manipulation of the supplied .ini file, then uploading it via the web interface. This method is
recommended for a quick start scenario. The I3 supplied .ini file, with just a few modifications will
get a basic setup up and running. Please note, the I3 supplied .ini file is not meant to be a drop in
configuration for every environment, it is provided as reference only.
Web interface - This method was used to configure the unit during validation. There are many
advanced options that are exposed in the web interface. Caution should be exercised and the
Audiocodes documentation should always be referenced when using the web interface
configuration option.
TFTP - This has not been tested.
Initial Setup:
Unzip the ZIP file containing the Mediant 1000 configuration files and firmware.
Follow the AudioCodes instructions (on the CD or in the booklet shipped with the Mediant 1000 or
in) for getting an IP address assigned to the MP box.
Modify the I3 provided .ini file as appropriate.
Start a web browser and type in the IP address of the Mediant 1000.
The default user name is “Admin” (with a capital “A”) and the password is “Admin” (with a capital
“A”). It is recommended to change the password at this time for security reasons.
Download Current Firmware (CMP file):
From the main web screen, select Software Update from the icons on the left side of the page.
Depending on what version of firmware is currently running on the Mediant 1000, two options will
be available, “Software File-Download” or “Software Upgrade Wizard”
Choose the appropriate option and load the validated version of firmware onto the Mediant 1000.
After the validated firmware has been applied the Mediant 1000 will restart. Once the restart is
complete, return to the web interface and click on “Status & Diagnosticson the left hand side of
the screen. Then select “System Information” from the top of the screen. The displayed Version
ID should match the firmware version as noted in section 1.1.3. If it does not, double check the
upgrade steps and consult the AudioCodes documentation if necessary.
Download Auxiliary File(s):
From the Software Update Section, select “Load Auxiliary Files”
Click the browse button to select the auxiliary file to download, then click “Send File.”
During the validation procedure, the only auxiliary file option tested was the E&M Wink CAS file
for T1 signaling.
Repeat the steps in this section any additional auxiliary files required for this installation.
Modularity Support:
The Mediant 1000 with firmware version 5.x now supports modularity. Both analog and digital
modules can be purchased in the following configurations:
1,2,or 4 port Digital Modules (E1, T1, ISDN)
2 or 4 port FXS analog module
2 or 4 port FXO analog modules
Up to six of these modules can be installed in the Mediant 1000 and can be field upgraded.
Configuration is consistent with all the other AudioCodes Analog and Digital gateways except for
the configuration of the FXS station extensions. Two differences when configuring the FXS
stations are:
To configure FXS station extensions a trunk group is created with the appropriate
port mod/port number with the extension of the FXS phone. (Figure 1)
An entry is created in the “IP to Trunk Group Routing Table” to direct the
incoming SIP station calls to the appropriate trunk group. (Figure 2)