AudioCodes Mediant Series Especificaciones Pagina 27

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 136
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 26
Spectralink 84-Series with AudioCodes Gateway and Avaya Communication Manager: Interoperability Guide
1725-86914-000_C.docx
September 2013 27
T1/E1 Module
The chassis supports up to four digital E1/T1/J1 modules. The module is available in 1-, 2-, or 4-
span configurations, providing RJ-48c ports (not RJ45). The ports are labeled I, II, III, and IIII.
The maximum number of ports that can be utilized is four.
Note: T1 Module
The T1 Module is shipped separately from the chassis.
Each port provides a LED that indicates operating status.
Color
State
Description
Green
On
Trunk is synchronized (normal operation)
Red
On
Loss due to:
LOS Loss of Signal
LOF Loss of Frame
AIS Alarm Indication Signal (the Blue Alarm)
RAI Remote Alarm Indication (the Yellow Alarm)
-
Off
Failure or disruption in the AC power supply or the power is currently not being
supplied to the device through the AC power supply entry.
Vista de pagina 26
1 2 ... 22 23 24 25 26 27 28 29 30 31 32 ... 135 136

Comentarios a estos manuales

Sin comentarios