¾ To configure the SPD table using the Embedded Web Server, take
these 6 steps:
1. Access the Embedded Web Server (refer to Section 5.3 on page 58).
2. Open the ‘IPSec Table’ screen (Advanced Configuration menu > Security Settings
> IPSec Table option); the ‘IPSec Table’ screen is displayed.
Figure 13-5: IPSec Table Screen
3. In the ‘Policy Index’ drop-down list, select the rule you want to edit (up to 20 rules can
be configured).
4. Configure the SPD parameters according to Table 13-3 on page 286.
5. Click the button Create; a row is create in the SPD table
6. To save the changes so they are available after a power fail, refer to Section 5.9.2 on
page 124.
To delete a peer from the SPD table, select it in the ‘Policy Index’ drop-down list, click the
button Delete and click OK at the prompt.