AudioCodes MEDIAPACK VERSION 6.2 Manual de usuario Pagina 32

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 51
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 31
CTM; Reviewed:
SPOC 11/29/2007
Solution & Interoperability Test Lab Application Notes
©2006 Avaya Inc. All Rights Reserved.
32 of 51
AudioCodesMP118.doc
Step Description
12.
General Advanced Parameters
From the menu shown in Step 11, navigate to Advanced Parameters Æ General
Parameters. Configure the parameters as described below.
Select Enable for the Enable Polarity Reversal and Enable Current
Disconnect fields. This will allow the MP-118 to provide the proper
disconnect indication to various line types.
In the Max Number of Active Calls field, enter a value that is equal to or
greater than the maximum number of ports (FXS + FXO) available on the
gateway. For the compliance test, there were 4 FXS ports and 4 FXO ports.
Default values may be retained for all other fields. Click Submit.
Vista de pagina 31
1 2 ... 27 28 29 30 31 32 33 34 35 36 37 ... 50 51

Comentarios a estos manuales

Sin comentarios