Vista de pagina 41
Microsoft Lync and ThinkTel SIP Trunk
AudioCodes Mediant E-SBC Series 42 Document #: LTRT-38110
4.7 Step 7: Configuring SIP TLS Connection
This step shows how to configure AudioCodes devices for a TLS connection with the
Microsoft Lync Mediation server. This is essential for a secure SIP TLS connection.
4.7.1 Step 7-1: Configuring NTP Server
This step shows how to configure the NTP Server IP address. It is recommended to
implement a 3
rd
party NTP server so that the E-SBC device receives the accurate current
date and time. This is necessary for validation of remote parties' certificates.
¾ To configure NTP Settings:
1. Open the Application Settings page (Configuration tab > System menu >
Application Settings).
Figure 4-18: NTP Settings
2. Set the NTP Server IP Address to <NTP Server IP-Address> (e.g., 10.15.9.10).
2